Return to flip book view

Fail-Safe GAC Germicidal Air

Page 1

Project Catalog # TypePrepared by Notes DatePS519421EN page 1April 29, 2021 9:29 AMTop Product Features• Able to be used in occupied spaces • Designed to use the latest in Germicidal UV source technology• Fits in a 2x2 grid opening• Symmetrical Coverage Area• Horizontal distribution keeps GUV in upper air• UL 1598 ListedTypical ApplicationsRetail • Commercial • Education • HospitalityFail-SafeGAC Germicidal Air Ceiling MountGermicidal Air Disinfection 2x2 SuspendedTrusted35 years experience in UV-C disinfection and strong application expertise. EffectiveProven effectiveness against bacteria, mold, mildew, and viruses.ContinuousCan be used in occupied spaces.VersatileCan be used in numerous applications.Pure protection against bacteria and viruses using the power of lightInteractive Menu• Order Information page 2• Germicidal Energy Distributions page 3• GUV Education page 4• Product WarrantyProduct CerticationProduct FeaturesGERMICIDALCHEMICAL FREEDISINFECTION CYCLEBlack FinishWhite Finish

Page 2

GAC Germicidal UV Air Ceiling MountPS519421EN page 2April 29, 2021 9:29 AMFail-SafeProduct SpecicationsGermicidal UV• Germicidal UV source technology using quartz enclosure and long-life igniter to maximize the run time and ensure optimal germicidal eciency• Utilizes GUV sources operating at 254nm wavelength• GUV is a proven disinfection technology effective on pathogens including mold, fungi, bacteria, and viruses• GUV power is delivered up to 9000 hours while maintaining at least 80% of the initial GUV energy• Rapid Start electronics extend the life to up to 25,000 start-up cyclesConstruction• Die-formed steel housing• Emitter included with xtureFinish• Polyester powdercoat nish on housing and endcaps • Matte white and low-gloss black standard nishes available • Louvers standard with black nishOptics• Reector made of specular aluminum specically tuned to maximize the germicidal energy output• Louvers limit reectivity of germicidal energy outside of the horizontal plane to comply with IEC 62471 Photobiological Risk Group 0 classication• Distribution focuses disinfection energy where it is needed, maximizing eciencyMounting• Fits in 2x2 Ceiling Grid• Minimum ceiling height of 9ft• Minimum recommended spacing is 12ft on center and 6ft from nearest wall• Professional layouts can be completed by Cooper Lighting Solutions upon requestCompliance• This GUV product is designed to comply with Risk Group 0• UL 1598 listed GUV xture• UL1598 annex L states it is the responsibility of the installer to ensure that persons will not be exposed to excessive UV or optical radiation during equipment operation. This will require the installer to conduct an assessment of irradiance levels in the surrounding occupied spaces prior to occupancy. • Product complies with FCC part 18 limits• This device has not been evaluated by the FDA, and is not approved for use in medical applications• EPA Facility # 095792-CAN-1Warnings and Safety• GUV Sources emit high-power UV radiation that can cause severe injury to skin and eyes. Avoid eye and skin exposure to unshielded products.• GUV may cause degradation and fading of paints, fabrics and other materials• Plants and/or materials that are exposed to UV-C and/or ozone for a long time may become damaged and/or discoloredShipping and Electrical DataCatalog No. Wattage Wt.22GAC-4GUV9W-UNV-R1-W 36.2 30 lbs22GAC-4GUV9W-UNV-R1-B 36.2 30 lbsNote: Sources are sold with the xture but ship uninstalled in packaging.Order InformationSAMPLE ORDER NUMBER: 22GAC-4GUV9W-UNV-R1-WFixture No. of Sources Source Type Wattage Voltage Driver Finish AccessoriesFixture No. of Sources Source Type Wattage Voltage Driver Finish Finish22GAC=Germicidal Air Ceiling Mount4=4 Sources GUV=Germicidal UV Emitter 9W UNV=Universal Voltage 120-277VR1=Single Rapid Start Driver W=White B=BlackDF-22W-U=2x2 Drywall KitReplacement PartsReplacement PartsGUV-LAMP-9W-U=9W TUV Replacement SourceBAL-GAC-4/9W-R-PK=Replacement 4/9W-emitter Rapid Start DriverGAC-GRID-CLIP-PK=Replacement Grid Clips

Page 3

GAC Germicidal UV Air Ceiling MountPS519421EN page 3April 29, 2021 9:29 AMFail-SafeView IES filesGermicidal Energy DistributionSpacing criteria is based on optical only. For GUV layouts, this will depend on dosing needed and the time desired to disinfect the desired area.Dimensional and Mounting Details23-3/4" [603mm]19-3/4" [502mm]7-1/4"[183mm]6-11/32"[161mm]23-3/4" [603mm]23-3/4"[603mm]90-deg 135-deg180°170°160°150°140°130°120°110°100°90°80°70°60°50°40°30°20°10°0°0-deg 45-deg507 mW/SR380 mW/SR254 mW/SR127 mW/SR0.022GAC-4GUV9W-UNV-R1-WElectronic Driver4 GUV SourcesIrradiance (mW): 298Input Watts: 36WTest Report: 22GAC-4GUV9W-UNV-R1-W.IES

Page 4

GAC Germicidal UV Air Ceiling MountCooper Lighting Solutions1121 Highway 74 SouthPeachtree City, GA 30269P: 770-486-4800www.cooperlighting.com© 2021 Cooper Lighting SolutionsAll Rights Reserved. Specifications and dimensions subject to change without notice.PS519421EN page 4April 29, 2021 9:29 AMFail-SafeGUV EducationFor more information on Fail-Safe GUV Disinfecting Solutions,please visit www.cooperlighting.com/GUV100 200 280 315 400 780GUV Disinfection 254nm “Near-UV” Violet 405nmX-rays Ultraviolet InfraredVisibleUV-C UV-BVacuumUVUV-A• GUV (germicidal ultraviolet) is a proven and effective disinfection technology.• GUV refers to short-wavelength ultraviolet “light” outside of the visible spectrum that is proven to kill bacteria and inactivate viruses...FAST! These short wavelengths in the photobiological UV spectral band known as “UV-C” are centered at 254nm, which is the optimal source wavelength for eliminating pathogens.• GUV is an excellent air disinfectant due to its quick germicidal efficacy.• Germicidal effectiveness is determined by the “fluence” or germicidal irradiance dose in the air.• GUV can pose a safety and health hazard to the eyes and skin if the product is improperly used or installed.• Follow recommended practices for utilization and control of GUV fixtures.Air flows into the zone ofdisinfecting irradianceDisinfected air flows down to thelevel where people are presentGermicidal UV Air Disinfection fixture produces horizontal distribution,keeping GUV above the level where it will affect peopleGermicidal UV disinfects air in theupper portion of the space